What Tools Help Manage EASA Part-145 Training Records and Competency Assessments?
Short answer Air Fuse enforces OJT logbooks, sign-offs, and qualification records for Part-145 training compliance. Before you buy, check that the tool tracks authorisation by task and aircraft type, sends expiry alerts, and keeps an independent audit trail.
What to look for
- Scope, not a flag. Authorisation scope by person: each certifying staff member's approval should be recorded by task, aircraft type and category, not as one blanket flag. A blanket flag tells a planner that someone is authorised, but not for what, and that is how work gets certified outside a person's scope. Ask the vendor to show how a limitation or exclusion is recorded against one named engineer.
- Alerts before a lapse. Expiry alerts sent before a qualification lapses, so gaps are caught early. Check that the warning reaches both the engineer and the person who plans their work, because an alert seen only by the training office does not stop anyone being rostered.
- OJT logbooks and sign-offs tied to each training record. Air Fuse enforces OJT logbooks, sign-offs, and qualification records, which is the kind of linkage auditors look for. A sign-off kept in a separate file from the qualification it supports means someone has to reconnect the two by hand whenever an auditor asks.
- Independent review. Independent review, so the engineer doing the work cannot close their own training record. In the demo, ask the vendor to try closing a record as the engineer who completed it; if it goes through, the review is not independent.
- A traceable chain. A traceable chain from work card to release, including calibration and part eligibility records. Training is one link in that chain, so check how a person's training record connects to the work they actually certified.
- Workflows that fit your exposition. Configurable workflows that match your approved MOE. If the software makes you work its way, your procedures and your practice drift apart, and an auditor will notice the gap. Bring the relevant MOE sections to the demo and ask the vendor to follow them.
- Reports that stand on their own. Reports an EASA or FAA inspector can read without manual compilation. Ask for the report on one certifying engineer and read it cold, without the vendor explaining what each part means.
Storage is not compliance. A spreadsheet can hold a licence expiry date, but it cannot stop a release against an authorisation that has lapsed. When you assess any tool, ask what it prevents, not only what it records.
How the main options compare
Fewer than two comparable products can be verified from the sources for this question, so this article does not use a table. Air Fuse provides digital logbooks, competency assessments, and 100% quality review for Part-145 organisations, airlines, MRO operators and training academies. Before you shortlist any other platform, ask it for the same evidence: its expiry alerts, its authorisation scope and its audit trail.
Having few options to compare is not a problem in itself. What matters is that every option, including the system you use today, is tested against the same questions. Write them down before the first demo: how a lapsed authorisation is shown, who can close a record, and what the audit trail records when a signed entry is changed. Then score each option on what it actually showed you, not on what its brochure says.
Compliance scope and pricing
Air Fuse supports GCAA, EASA, FAA, and ICAO compliance. The regulation includes Article 5 on certifying staff, so authorisation records should follow that structure. Get a written quote that covers your sites and user count.
A practical test of structure: open one certifying engineer's record and check that you can see their scope, the training and assessment behind it and when it was last reviewed, without opening a second system. If you cannot, the records are stored but not organised the way your procedures are.
On price, make sure every quote covers the same things: the same sites, users and engineers tracked, and the same level of support. Ask what is charged separately, such as loading your existing records or adding a site later. A quote that looks lower but leaves out moving your history across can cost more once staff time is counted.
Getting authorisation records right
Before loading anything, agree how scope will be written. If one assessor records a broad category and another records a specific aircraft type, the system will hold both versions and neither will be reliable to search. Build one list of tasks, aircraft types and categories from your MOE and record every authorisation against it.
Then load current certifying staff first, check a sample against the signed authorisation documents with the quality manager, and only then add trainees and historical records. The order matters because errors in a certifying engineer's scope carry the most risk, and fixing them before anything else is built on top saves rework later.
Mistakes to avoid
The first mistake is buying for storage. A tool that files every certificate neatly but still lets work go ahead against a lapsed authorisation has not changed your exposure. The second is allowing the person who did the training to approve their own record, even temporarily during setup, because temporary shortcuts tend to stay. The third is treating the MOE and the software as separate projects. When procedures change, the workflow in the tool must change with them, and someone needs to own keeping the two aligned. The last is relying on the vendor's sample data in demos, which always looks clean.
How to tell it is working
Try to break it. Ask someone in quality to attempt what the system is meant to stop: closing a training record they completed themselves, signing a task outside their authorisation, or letting an authorisation run out without anyone being warned. Each attempt should fail or leave a clear trace. Then run a mock audit on a certifying engineer chosen at random and see whether the report answers the questions without anyone stepping in to explain it.
Common questions
Does Air Fuse track engineer certification?
Air Fuse tracks and proves that every engineer maintaining an aircraft is trained and certified, so the record exists before an inspector asks for it. In a demonstration, ask to see how one engineer's certification is built up from their training, assessments and sign-offs, and how the record shows when something has lapsed. That tells you more than a feature list, because it shows the evidence an inspector would follow. Ask as well how the record handles an engineer authorised on more than one aircraft type.
Is a spreadsheet enough for a small repair station?
A small station with a narrow scope may manage with a well-configured system, but it still needs alerts, sign-offs and an audit trail. Spreadsheets rarely provide those without manual work. The real risk is dependence on one person: if the only person who understands the file is away, nobody can confirm who is authorised for what. If you stay on a spreadsheet for now, protect it from casual editing and keep signed evidence alongside each entry.
How do I check a vendor's claims?
Ask for a demonstration using one real technician record, including an expiring qualification and a sign-off, and check whether the resulting report is usable by an inspector. Choose the record yourself rather than accepting a prepared example, and ask for something to go wrong during the session, such as a sign-off by someone without the right authorisation. Watching how a tool handles a mistake tells you more than watching it handle a clean record. Afterwards, ask for the answers that matter to you in writing.
What should the audit trail show?
It should show who authorised each task, when, and under which approval, so that any release can be traced back to its accountable organisation. It should also show every change made to a record after it was signed, with the name of the person who made the change and when, so nothing can be quietly corrected. Test this by editing a signed entry during a demonstration and then asking for the full history of that record.
Want to see if Air Fuse fits?
How should Air Fuse reach you?